Victron Energy SMART BMS 12/200

Victron Energy SMART BMS 12/200

Smart BMS 12V/200A Battery Management System for Victron Lithium Iron Phosphate (LiFePO4) Smart Batteries. BMS210055000

Smart BMS 12/200 - Protects the alternator against overload.

Battery Management system
The BMS connects to 12,8V Victron LiFePO4 (LFP) batteries. Up to 5 batteries may be connected in parallel. Can be used as a system on/off switch.

Starter battery Protection
This function is similar to that of a Cyrix Battery Combiner or Argo FET Battery Isolator. Current can flow to the LFP battery only if the input voltage (= voltage on the starter battery) exceeds 13V.
Additionally current cannot flow back from the LFP battery to the starter battery, thus preventing eventual damage to the LFP battery due to excessive discharge.

Alternator and battery protection
The input current is electronically limited to approximately 90% of the fuse rating. A 100A fuse, for example, will therefore limit the input current to approximately 90A.
Choosing the right fuse will:
a. Protect the LFP battery against excessive charge current (important in case of a low capacity LFP battery).
b. Protect the alternator against overload in case of a high capacity LFP battery bank (most 12V alternators will overheat and fail if running at maximum output during more than 5 minutes).

Load/battery charger output-input (Power Port SYSTEM+)
This Power Port can be used to either charge or discharge the LFP battery (i.e. via a charger, an inverter or inverter/charger) with a maximum continuous current of 200A in both directions.
Can also be used as a load output, thus DC loads can be connected directly to this port. The port is short-circuit protected with a peak discharge current of 400A.
The Smart BMS will make sure that the battery discharge will cut-off in case of imminent cell under voltage.
The Smart BMS will enable charging through this port, but no charge algorithm can be applied internally.

Li-ion battery protection
Excessive input voltage and transients are regulated down to a safe level. The Smart BMS will stop charging in case of cell over voltage or over temperature. It has three outputs, similar to the smallBMS:

  • Load Disconnect output
    The Load output is normally high and becomes free floating in case of imminent cell under voltage (default 2.8V/cell, adjustable on the battery between 2.6V and 2.8V per cell). Maximum current: 10mA. The Load output can be used to control the remote on/off input of a Battery Protect, inverter, DC-DC converter or other loads.
  • Pre-Alarm output
    The pre-alarm output can be used as warning when the battery voltage is low and it will trip shortly before the Load Disconnect output is disabled due to cell under voltage.
    The pre-alarm output may be used to drive a relay, LED or Buzzer. It can be configured as continuous or intermittent signal.
    The pre-alarm output is normally free floating and becomes high in case of imminent cell under voltage (default 3.1V/cell, adjustable on the battery between 2.85V and 3.15V per cell). Maximum current: 1A (not short circuit protected)
    The minimum delay between pre-alarm and load disconnect is 30 seconds.
  • Charge disconnect output
    The Charge disconnect output is normally high and becomes free floating in case of imminent cell over voltage or over temperature. Maximum current: 10mA. The Charge disconnect output is not suitable to power an inductive load such as a relay coil. The Charge disconnect output can be used to control: the remote on/off of a charger, a Cyrix-Li-Charge relay, a Cyrix-Li-ct Battery Combiner.
    (Note: in some cases an interface cable will be needed, please see the manual.)

Remote on/off input
The remote on/off input controls the charging via the alternator. When off, charging via the alternator is disabled, while the BMS functionality will remain active allowing any loads and chargers to continue working regardless of the state of the remote input.
When “system on/off switch” is enabled via VictronConnect, the BMS functionality will also be disabled.
It consists of two terminals: Remote L and Remote H. A remote on-off switch or relay contact can be connected between H and L.
Alternatively, terminal H can be switched to battery plus, or terminal L can be switched to battery minus

Ignition proof
No relays but MOSFET switches, and therefore, no sparks.

This package comes supplied with:

  • Smart BMS 12V/200A

Related Products


SHARE:
Selling Unit EACH
Model No SMART BMS 12/200
Brand Victron Energy brand logo
Original Brand Victron Energy BMS210055000
Description Smart BMS 12V/200A Battery Management System for Victron Lithium Iron Phosphate (LiFePO4) Smart Batteries. BMS210055000
Width 120mm
Height 65mm
Length / Breadth / Depth 340mm
Weight 2000g
Categories Power Products & Accessories
Battery Management & Monitoring
External Master BMS
External Master BMS for 12V
Data Sheet Datasheet PDF Thumbnail icon Datasheet PDF Thumbnail icon

Login to MI Link for pricing
Login for Pricing
MI Link is a dealer-only portal. If you are not a current MI account holder register for an account

Victron Connect app compatible

VictronConnect Compatible

VictronConnect lets you get live status information and configure any Victron Energy products via either Bluetooth or direct cable connection. Connect to Bluetooth equipped products, or non-Bluetooth equipped products using VE.Direct Bluetooth Smart Dongle. Connect directly to equipment using the VE.Direct to USB Interface (USB Type-A) or VE.Direct to Type C Interface (USB Type-C) cables.

Find out more about VictronConnect here, or download the App via these links. Click here to download the VictronConnect Manual.

Apple App Store

Apple Mac store

Google Play Store

Windows Download

Back to the top of page MI Link Contact Us