Sieltec VG-AGS-1

Sieltec VG-AGS-1

Voltgo Battery Generator Interface to Start and Stop a Generator

The Sieltec VG-AGS-1 is a programmable generator start interface that sits between a Victron CerboGX (or similar battery management controller) and a marine or stationary generator.

It converts the single relay contact closure output of the CerboGX into the correctly timed start and stop pulses required by the generator — removing the need for discrete timer relays and the associated custom wiring that would otherwise be required for each installation.

The device was developed specifically to solve a recurring installation problem: connecting the CerboGX's relay output to generators such as the Cummins Onan and Kohler marine gensets, which require distinct timed pulses rather than a simple sustained contact closure.

The VG-AGS-1 packages that function cleanly into a compact, panel-mount enclosure with a simple front-panel programming interface, a manual start/stop test function, and a dedicated disable button — ideal for vessels being lifted from the water where an inadvertent autostart of a water-cooled generator must be prevented.

*Suitable for use with the 12V and 24V systems

Key Features:

  • Converts CerboGX relay contact closure to timed start and stop pulses for compatible generators
  • Fully programmable start pulse duration, stop pulse duration, and inter-pulse separation via front-panel buttons and OLED display
  • Supports generators with separate start/stop circuits or shared single-circuit start/stop (join start and stop outputs)
  • Built-in manual Start and Stop buttons — allows installer to verify generator wiring before connecting the CerboGX
  • Dedicated Disable/Enable button — disables autostart function (e.g. vessel out of water)
  • Reverse polarity protected power input
  • OLED display with auto-dim (after 1 hour inactivity); reactivates on any button press or trigger
  • Pluggable spring push-button connectors (Phoenix 2.5 mm pitch) — no tools required for field wiring
  • High electrical noise immunity — unshielded multicore cable is sufficient
  • Flame-resistant ABS enclosure, UL94-V0

Please Note: The AGS-1 does not detect whether the generator has successfully started, does not retry on a failed start, and does not monitor generator alarms. It is a pulse interface only.

Typical Schematic

VG-AGS-1 Schematic

 

The VG-1BM can be used in conjunction with a Victron Energy GX device to also provide additional information to those systems.

VoltGo Range Link Icon
Click here to view the VoltGo lithium battery range

 


Selling Unit EACH
Model No VG-AGS-1
Brand Sieltec brand logo
Description Voltgo Battery Generator Interface to Start and Stop a Generator
Categories Power Products & Accessories
Battery Management & Monitoring
Sieltec
VoltGo Battery Accessories
Data Sheet Datasheet PDF Thumbnail icon

Login to MI Link for pricing
Login for Pricing
MI Link is a dealer-only portal. If you are not a current MI account holder register for an account

Back to the top of page MI Link Contact Us